1,560 research outputs found

    Endovascular treatment of thoracic aortic disease: Four years of experience

    Get PDF
    Background-The aim of this retrospective study is to investigate efficacy and middle-term results of the stent graft treatment for diseases of descending thoracic aorta. Methods and Results-From March 1999 to October 2003, 132 patients (113 male and 19 female, mean age 62±14 years) were enrolled. They were divided into 4 groups: aneurysms (43, group A), post-traumatic lesions (24, group B), and complicated type B dissections (43, group C). Twenty-two further patients, with chronic type B dissection and not suitable for endovascular or surgical or hybrid techniques because of multiple entry tears without difference between the true and false lumen and poor clinical conditions, were obliged to receive medical management only (group D). All patients underwent computed tomography (CT) scan and angiography as preoperative assessment. An optimal deployment with exclusion of the aneurysm and/or closure of the entry tear in dissection was achieved in 96.4% (106/110) of the patients that were discharged in good conditions within 6 days. No spinal cord injuries were observed. The follow-up (average 20.82±10.01 months, range 1 to 55 months), performed with serial chest CT scans, was 100% complete. No stent graft-related complications were detected, although only in 1 case, an asymptomatic rupture of the Excluder connecting bar was found with a perforation of the fabric and an intra-aortic exposition of the bar itself. In 2 patients with chronic dissection an asymptomatic type II endoleak was detected. A total of 4 hospital deaths resulted in an overall operative mortality of 3.9%. Seven patients (6.3%) died during the follow-up 5 of them for other diseases (4.5%). However, a 40.9% mortality was observed within the obliged medical treatment group. Conclusions-Endovascular treatment of thoracic aortic diseases, even in the acute phase, may represent a valid option with a low mortality rate. Moreover, the efficacy is proved in the middle-term whereas the long-term follow-up is still pending

    Construction and Performance of Large-Area Triple-GEM Prototypes for Future Upgrades of the CMS Forward Muon System

    Get PDF
    At present, part of the forward RPC muon system of the CMS detector at the CERN LHC remains uninstrumented in the high-\eta region. An international collaboration is investigating the possibility of covering the 1.6 < |\eta| < 2.4 region of the muon endcaps with large-area triple-GEM detectors. Given their good spatial resolution, high rate capability, and radiation hardness, these micro-pattern gas detectors are an appealing option for simultaneously enhancing muon tracking and triggering capabilities in a future upgrade of the CMS detector. A general overview of this feasibility study will be presented. The design and construction of small (10\times10 cm2) and full-size trapezoidal (1\times0.5 m2) triple-GEM prototypes will be described. During detector assembly, different techniques for stretching the GEM foils were tested. Results from measurements with x-rays and from test beam campaigns at the CERN SPS will be shown for the small and large prototypes. Preliminary simulation studies on the expected muon reconstruction and trigger performances of this proposed upgraded muon system will be reported.Comment: 7 pages, 25 figures, submitted for publication in conference record of the 2011 IEEE Nuclear Science Symposium, Valencia, Spai

    An overview of the design, construction and performance of large area triple-GEM prototypes for future upgrades of the CMS forward muon system

    Get PDF
    GEM detectors are used in high energy physics experiments given their good spatial resolution, high rate capability and radiation hardness. An international collaboration is investigating the possibility of covering the 1.6 < vertical bar eta vertical bar < 2.4 region of the CMS muon endcaps with large-area triple-GEM detectors. The CMS high-eta area is actually not fully instrumented, only Cathode Strip Chamber (CSC) are installed. The vacant area presents an opportunity for a detector technology able to to cope with the harsh radiation environment; these micropattern gas detectors are an appealing option to simultaneously enhance muon tracking and triggering capabilities in a future upgrade of the CMS detector. A general overview of this feasibility study is presented. Design and construction of small (10cm x 10cm) and full-size trapezoidal (1m x 0.5m) triple-GEM prototypes is described. Results from measurements with x-rays and from test beam campaigns at the CERN SPS is shown for the small and large prototypes. Preliminary simulation studies on the expected muon reconstruction and trigger performances of this proposed upgraded muon system are reported

    Triggering events with GPUs at ATLAS

    Get PDF
    The growing complexity of events produced in LHC collisions demands increasing computing power both for the online selection and for the offline reconstruction of events. In recent years there have been significant advances in the performance of Graphics Processing Units (GPUs) both in terms of increased compute power and reduced power consumption that make GPUs extremely attractive for use in a complex particle physics experiments such as ATLAS. A small scale prototype of the full ATLAS High Level Trigger has been implemented that exploits reconstruction algorithms optimized for this new massively parallel paradigm. We discuss the integration procedure followed for this prototype and present the performance achieved and the prospects for the future.Peer Reviewe

    An evaluation of GPUs for use in an upgraded ATLAS High Level Trigger

    Get PDF
    ATLAS is a general purpose particle physics experiment located on the LHC collider at CERN. The ATLAS Trigger system consists of two levels, the first level (L1) implemented in hardware and the High Level Trigger (HLT) implemented in software running on a computing cluster of commodity CPUs. The HLT reduces the trigger rate from the 100 kHz L1 accept rate to 1 kHz for recording, requiring an average per-event processing time of ~300 ms for this task. The HLT selection is based on reconstructing tracks in the Inner Detector and Muon Spectrometer and clusters of energy deposited in the calorimeters (electromagnetic and hadronic). Performing this reconstruction within the available HLT computing cluster resources presents a significant challenge. Future HLT upgrades will result in higher detector occupancies and, consequently, will harden the reconstruction constraints. General purpose Graphics Processor Units (GPGPU) are being evaluated for possible future inclusion in an upgraded HLT computing cluster. We report on a demonstrator that has been developed consisting of GPGPU implementations of the calorimeters clustering and Inner Detector and Muon tracking algorithms integrated within the HLT software framework. We give a brief overview of the algorithm implementation and present preliminary measurements comparing the performance of the GPGPU algorithms with the current CPU versions.Peer Reviewe

    Preliminary experience with the smooth muscle troponin-like protein, calponin, as a novel biomarker for diagnosing acute aortic dissection

    Get PDF
    Aims The early diagnosis of acute aortic dissection (AD) remains challenging. We sought to determine the utility of the troponin-like protein of smooth muscle, calponin, as a diagnostic biomarker of acute AD. Methods and results Immunoassays against calponin (acidic, basic, and neutral isoforms) were developed and the levels were compared in a convenience sample of 59 patients with radiographically proven AD [34 males, age 59+15 (SD) years] vs. 158 patients suspected of having AD at presentation (116 males, age 63+15 years) but whose final diagnosis was not AD. Basic calponin, which is the most specific and abundant in smooth muscle, and acidic calponin, respectively, showed greater than two-fold and three-fold elevations in patients with acute AD. Diagnostic performance as determined by receiver-operating characteristics curve analysis showed that both acidic and basic calponin have the potential to detect AD in the first 24 h [respective areas under the curve (AUCs) 0.63 and 0.58], with superior performance of basic calponin (when compared with acidic) in the initial 6 h (respective AUCs 0.63 and 0.67). Conclusion Circulating calponin levels were elevated in acute AD compared with controls. These biomarkers have the potential for use as an early diagnostic biomarker for acute AD. Keywords Aortic dissection ? Biomarke

    Search for the standard model Higgs boson in the H to ZZ to 2l 2nu channel in pp collisions at sqrt(s) = 7 TeV

    Get PDF
    A search for the standard model Higgs boson in the H to ZZ to 2l 2nu decay channel, where l = e or mu, in pp collisions at a center-of-mass energy of 7 TeV is presented. The data were collected at the LHC, with the CMS detector, and correspond to an integrated luminosity of 4.6 inverse femtobarns. No significant excess is observed above the background expectation, and upper limits are set on the Higgs boson production cross section. The presence of the standard model Higgs boson with a mass in the 270-440 GeV range is excluded at 95% confidence level.Comment: Submitted to JHE

    Measurement of the t t-bar production cross section in the dilepton channel in pp collisions at sqrt(s) = 7 TeV

    Get PDF
    The t t-bar production cross section (sigma[t t-bar]) is measured in proton-proton collisions at sqrt(s) = 7 TeV in data collected by the CMS experiment, corresponding to an integrated luminosity of 2.3 inverse femtobarns. The measurement is performed in events with two leptons (electrons or muons) in the final state, at least two jets identified as jets originating from b quarks, and the presence of an imbalance in transverse momentum. The measured value of sigma[t t-bar] for a top-quark mass of 172.5 GeV is 161.9 +/- 2.5 (stat.) +5.1/-5.0 (syst.) +/- 3.6(lumi.) pb, consistent with the prediction of the standard model.Comment: Replaced with published version. Included journal reference and DO

    Search for anomalous t t-bar production in the highly-boosted all-hadronic final state

    Get PDF
    A search is presented for a massive particle, generically referred to as a Z', decaying into a t t-bar pair. The search focuses on Z' resonances that are sufficiently massive to produce highly Lorentz-boosted top quarks, which yield collimated decay products that are partially or fully merged into single jets. The analysis uses new methods to analyze jet substructure, providing suppression of the non-top multijet backgrounds. The analysis is based on a data sample of proton-proton collisions at a center-of-mass energy of 7 TeV, corresponding to an integrated luminosity of 5 inverse femtobarns. Upper limits in the range of 1 pb are set on the product of the production cross section and branching fraction for a topcolor Z' modeled for several widths, as well as for a Randall--Sundrum Kaluza--Klein gluon. In addition, the results constrain any enhancement in t t-bar production beyond expectations of the standard model for t t-bar invariant masses larger than 1 TeV.Comment: Submitted to the Journal of High Energy Physics; this version includes a minor typo correction that will be submitted as an erratu
    corecore